NewsCenter
Location:Home > News Center
Clogging of the generator return line with a vacuum pump will cause undesirable consequences
[ Release Time:2017/8/10  Read:6070Times ]

When the generator vacuum pump works, the oil used will come from the main oil duct of the diesel engine. After the vacuum pump works, the oil will return to the diesel oil pan. If the return of the generator vacuum pump is blocked, the oil will be returned:
(1) the oil can not return smoothly, so that the rotor blade of the vacuum pump is broken easily, the vacuum is decreased or no vacuum.
(2) the oil return is not smooth, so that the generator rotor is subjected to reverse resistance (rotor resistance increases), and the generator rotor is easy to burn out.
(3) due to poor oil return oil return pipe is easy to be broken up.